TurboQ Real-time PCR System delivers reliable routine and multiplex qPCR with four optical channels and CCD imaging of the entire plate in a single read, ensuring time-synchronized, consistent data. The instrument offers ±0.25 °C accuracy and ±0.5 °C uniformity, plus a 60–99 °C gradient (up to 25 °C span) for fast, precise optimization. A motorized 96-well block (compatible with 0.2 mL tubes/strips and non/semi/full-skirted plates) handles 10–100 µL reaction volumes and is automation-ready via the motorized tray.
The all-in-one analysis software includes Absolute/Relative Quantitation, Allelic Discrimination, and Melting Curve—no add-on modules required. Typical uses span gene expression & quantification, pathogen/SNP multiplex detection, primer/probe verification, and method/QC workflows in R&D and molecular production.
Why labs choose TurboQ
- True 4-dye multiplex to cut reactions and per-run cost.
- Whole-plate CCD capture for consistent, time-aligned signals.
- Tight thermal control for stable Cq values.
- Complete software out of the box; no extra licensing.
- Automation-ready motorized plate handling for future scalability.
Additional information
| Status | New |
|---|---|
| Sample Block | Fixed 96-well, compatible with regular profile 0.2 ml PCR tube, strip, and semi-skirted 96-well plate |
| Sample Volume | 10 - 100 µl |
| Plate Loading | Motorized plate carrier tray |
| Block Temperature | |
| Block Temperature Range | 25 - 99 °C |
| Peak Block Ramp Rate | 2.5 °C/sec |
| Temperature Accuracy | ± 0.25 °C (35 °C – 95 °C) of set point/ display temperature / Measured at 3 minutes after clock start. |
| Temperature Uniformity Across Block | ± 0.5 °C (30 seconds after clock start) |
| Gradient Temperature | |
| Gradient Temperature Range | 60 - 99 °C |
| Gradient Temperature Difference | Max. span 25 °C |
| Heater Lid | |
| Heating Lid | 105°C |
| Optics | |
| Excitation Source | Tungsten-halogen lamp |
| Detection Module | CCD camera |
| Detection Channel | 4 channels (Ch1 |
| Environment | |
| Operating Temperature | 15 – 30 °C |
| Operating Humidity | RH |
| Storage Temperature | -10 - 60 °C |
| General | |
| PC Operation System | Windows 7 or higher |
| Footprint Dimensions (H x W x D) | 567 mm x 354 mm x 455 mm |
| Weight | 35 kg |
| Power Supply | 110/230 V, frequency 50/60 Hz, 1500W |
| Fuse | 1 x fuse, 10A for 110VAC power / 5A for 220VAC power |